Indoor air handling units (AHUs) for offices, shopping malls, clinics, warehouses and other commercial and municipal facilities require a combination of high efficiency, good acoustics and long service life. They reliably provide clean air to people in the buildings without creating drafts or irritating noise.
Energy efficiency and acoustics play a particularly important role in the design of the centrifugal fan used for air handling systems. But they should also be dimensioned to be as resource-efficient as possible in terms of space requirements and the effort required for installation and maintenance. The main component of a fan for influencing product characteristics is the fan wheel.
General HVAC blower wheels from punker therefore combine pleasant acoustics, compact design, flexible application options and very high static efficiencies. In this way, we support you in complying with strict legal guidelines and standards especially with regard to energy consumption such as Fan Energy Index (FEI) and CEC Appliance Efficiency Regulations.
General HVAC
punker General HVAC Fan Wheels
The fan impellers of the punker General HVAC series have been specially developed for use in air handling units that have to meet the highest energy efficiency requirements, such as those specified by the ErP Directive or the Fan Efficiency Index (FEI). With their impeller geometry optimized for efficiency, General HVAC fan impellers cover a very wide operating range with maximum efficiency. This gives manufacturers of air conditioning units and plug fans for AHUs the opportunity to drastically reduce their number of variants and thus the costs and effort involved in supplier and warehouse management.
Benefits
Reduced costs over the entire product life cycle:
- Thanks to the delivery of balanced fan impellers with low system vibrations, no rebalancing is necessary.
- Lightweight aluminum design facilitates installation, extends maintenance intervals and thus increases the service life of the motor used.
- The wheel strength, which is tailored to the load requirements, increases reliability during operation and thus reduces replacement intervals.
- The acoustically optimized wheel geometry enables use in noise-sensitive environments without incurring additional costs for insulation.
Enables compliance with strict legal guidelines and standards
- especially with regard to energy consumption such as Fan Energy Index (FEI) and CEC Appliance Efficiency Regulations.
Applications
- Air Handling Units (AHU)
- Compact air handling units
- Modular air handling units
- Plenum Fans / Plug fans
- Kitchen boxes
- Box fans
- Air Cleaners
Technical Data
Models | 16 diameters, one width each |
Diameters | 9" to 39" |
Material of construction | aluminum / steel / galvanized steel |
Inlet Cone | ED11 |
Wheel-motor-mount | Taperlock hub / fixed hub |

Downloads

Data Sheets | Impeller
General HVAC Fan Wheels
Sign in to download
Data Sheets | Inlet cones
Inlet Cone ED11
Sign in to download
Data Sheets | k-Factor
k-Factor ED11 | Dlight, Dclassic, Dprime, Aclassic, Bclassic
Sign in to download
Installation Instructions
(PDF, 415 KB)Find the optimum fan wheel in just 3 steps
With puncat WEB, you can carry out the preliminary selection of fan wheels directly on our website. Display suitable products for your application by determining the duty point, speed and diameter and specify your search via energy efficiency requirements, available installation space or maximum shaft power.
Start the Pre-SelectionCase Study Air Handling Units
Citizen Industries is a leading manufacturer of air handling units (AHU), laboratory equipment and biotech equipment in India. In 2016, punker helped Citizen reduce the number of different fan wheels in its AHUs by 90% by switching to the General HVAC Line. The rationalization has saved our customers time and money while further increasing the energy efficiency of Citizen's air handling units - which in turn helps end customers save on operating costs.
Read the case studyCase Study Hall Ventilation
A European developer and manufacturer of technologically sophisticated air conditioning solutions approached punker with the task of developing and supplying a new and optimized fan unit for an existing hall ventilation system within just three months. The punker solution included a conversion from forward to backward curved fan wheels, a custom laser-welded housing and the supply of complete fan units that provide a significant increase in energy efficiency and a substantial reduction in sound pressure.
Read the case studyGet a detailed quote from your contact in punker sales


Markus Rumswinkel
Area Sales Manager Americas
Phone:
+1.980.405.8823
E-Mail:
Markus.Rumswinkel@punker.com

For detailed technical information please contact our application expert

Matthias Wolf
Director of Engineering punker Group
Phone:
+49.4351.472.365
Mobile:
+49.172.583.8114
E-Mail:
Matthias.Wolf@punker.com

Write us!
Latest News from punker LLC
Tuesday, February 18, 2025
punker at AHR 2025: A successful showcase in Orlando
From February 10-12, 2025, punker was proud to be part of North America's largest trade show for data center cooling and building ventilation. At the AHR Expo we had the chance to showcase our cutting-edge, high-efficient fan wheels, designed to optimize air movement technology and improve performance across HVAC applications.
Wednesday, August 21, 2024
Visit us at AHR Expo 2025 in Orlando
From February 10th to February 12th, 2025 punker will be joining North Americas largest trade show for data center cooling and general building ventilation. Our company will be on side to present its latest and energy-efficient fan wheels for air movement technology.